The embedded network specialist
+31-40-2301.922

CANopen Master - EtherNet/IP gateway

Anybus CANopen master/slave to EtherNet/IP slave X-gateway

The Anybus X-gateway CANopen Master provides a seamless connection between a EtherNet-IP network and a secondary CANopen sub-network. This makes it possible to integrate CANopen devices in a EtherNet-IP system.
The gateway acts as a EtherNet-IP slave for the primary network and as a CANopen master or slave for the second network

With help of convenient configuration software it's easy to configure the data exchange bi-directional between both the networks.
X-gateway - CANopen Master - EtherNet-IP
Primary network
Primary network
X-gateway - CANopen Master - EtherNet-IP
X-gateway - CANopen Master - EtherNet-IP

Features and benefits

  • Fast copying of cyclic I/O data between a CANopen and EtherNet-IP network (5 ms)
  • Fulll CANopen Master/Manager functionality, eliminates the need for an PLC controller on the CANopen network
  • Connects up to 126 CANopen slave devices
  • Proven and tested with all PLC manufacturers
  • Easy CANopen configuration via the included Anybus Configuration Manager software. No programming required
  • Robust stand-alone housing for use in harsh industrial environments
  • Global free technical support and consultancy
  • Fast, dynamic transfer of fieldbus data to e.g. SCADA/HMI/Enterprise level systems based on Microsoft Windows, via the included Anybus OPC server

Fast copuing of I/O data

The X-gateway's primary function is fast transfer of cyclic I/O data between the EtherNet-IP and the CANopen network. I/O data from the PROFIBUS network is written into CANopen objects that can be mapped into CANopen PDOs and vice versa. The gateway acts as a full Master/Manager on the CANopen network and as a Slave on the EtherNet-IP network. The data transmission between the two networks is completely transparent with a maximum data capacity of 510 bytes in each direction

Easy configuration - No programming required!

CANopen configuration can easily be made through the included Anybus Configuration Manager CANopen software, or with any other standard CANopen configuration tool. No programming skills are needed.
The Anybus Configuration Manager scans the CANopen devices on the subnet. The software linked to the CAN bus by using a CAN interface which is available separately.

CANopen Master/Manager

  • CANopen Master/Manager implementation according to the CANopen specification DS301 v4.0.2.
  • Connects up to 126 CANopen slaves
  • Network Management (NMT) messages, to configure and initialize the network.
  • Supporting 128 Receive PDOs and 128 Transmit PDOs, each can transfer up to 8 bytes.
  • Up to 510 bytes of cyclic data in each direction (PDO)
  • PDO message types: COS (Change of State), Cyclic Synchronous, Acyclic Synchronous.
  • Synchronization Object (SYNC) is used for synchronizing PDO communication.
  • Heartbeat Mechanism to monitor the status of nodes.
  • Node Guarding/Life Guarding Protocol provides possibility to guard slaves or the master.
  • EMCY (Emergency Object) is used for error reporting.
  • LSS master functionality
  • Can also function as a CANopen Slave

EtherNet-IP Slave interface

EtherNet-IP Adapter settings can be made either via on-board switches, or by importing the provided .EDS file into engineering tool of the controlling PLC.
  • EtherNet-IP CONFORMANCE TESTED™ by ODVA
  • EtherNet-IP Level 2 I/O Server CIP
  • 10/100Mbit operation in full or half-duplex
  • Max. 509 bytes Input and 505 bytes Output data
  • Device Level Ring (DLR) functionality available (announce-based ring participant)
  • Integrated FTP server provides easy file management using standard FTP clients.
  • Web server with dynamic data capability and Server Side Include (SSI) capability
  • Email client with dynamic data capability and Event-triggered email handling
  • Per-user security framework
  • Quality of Service (QoS) available
  • DNS Capability
  • TCP/IP settings via DHCP/ARP/Anybus IPconfig (HICP)
  • Integrated switch allowing for a daisy-chain topology
Technische gegevens
Dimensions 120 x 75 x 27mm
Weight 150g
Operating temperature -25 to +55 °C
Storage temperature -40 to +85 °C
Power supply 24 VDC
Current consumption Typical 150mA
Configuration port USB
CAN  
  Baudrate 20 kbit/s - 1 Mbit/s
  Protocol support CAN 2.0A and 2.0B (11 and 29 bit identifiers)
  Connector D-sub 9 Male
EtherNet-IP  
  Connector 2x RJ45 (switch)
Galvanic isolation On both CAN and EtherNet-IP side
Protection class IP20
Mounting DIN-rail (EN 50022 standard)
Certifications CE, CULUS, ATEX/Haz.Loc, RoHS
Contents of delivery
- Anybus Communicator CAN-EtherNet-IP
- Anybus Configuration Manager (Windows™)
- Quick Reference Manual
- User Manual

Part number(s)

AB7306
Anybus X-gateway CANopen Master - EtherNet/IP, 1x CAN, 2x EtherNet/IP
Anybus X-gateway CANopen Master - EtherNet/IP, 1x CAN, 2x EtherNet/IP

Options

021670
Anybus Configuration Manager - Configuration Kit, incl. USB-to-CAN interface
 
 

Getting interested?

Are you interested in the CANopen Master - EtherNet/IP gateway? Please request, without any obligation, for a quote. Would you like more information? Please send an email to or visit our contact page.
You can call us if you like, we can be reached at +31-40-2301.922. We are pleased to help you and do offer you practical advice and support.

Related products

PC CAN-interfaces
CAN Repeaters
CAN Bridges & Gateways
Communicator CAN
CANopen PLC-extentions
canAnalyser 3 Suite
CAN Diagnostic Tools
CANopen Software
CAN Accessories